Randall Seifried
NYS Home Inspector
License #16000019077
Oswego Home Inspection

ABITCO Graduate
American Building Inspection
and Training Co. Inc.
|
| |
1.
Definitions and Scope
2.
Standards of Practice
2.1. Roof
2.2. Exterior
2.3. Basement,
Foundation, Crawlspace & Structure
2.4. Heating
2.5. Cooling
2.6. Plumbing
2.7. Electrical
2.8. Fireplace
2.9. Attic &
Insulation
2.10. Doors, Windows &
Interior
3. Limitations,
Exceptions & Exclusions
4. Glossary
of Terms
1.1. A Home Inspection is a non-invasive
visual examination of a residential dwelling, performed for a fee,
which is designed to identify observed material defects within
specific components of said dwelling. Components may include any
combination of mechanical, structural, electrical, plumbing, or
other essential systems or portions of the home, as identified and
agreed to by the Client and Inspector, prior to the inspection
process.
I. A Home Inspection is intended to
assist in evaluation of the overall condition of the dwelling.
The inspection is based on observation of the visible and
apparent condition of the structure and its components on the
date of the inspection and not the prediction of future
conditions.
II. A home inspection will not reveal
every concern that exists or ever could exist, but only those
material defects observed on the day of the inspection.
1.2. A Material Defect is a condition of a
residential real property or any portion of it that would have a
significant adverse impact on the value of the real property or that
involves an unreasonable risk to people on the property. The fact
that a structural element, system or subsystem is near, at or beyond
the end of the normal useful life of such a structural element,
system or subsystem is not by itself a material defect.
1.3. An Inspection report shall describe
and identify in written format the inspected systems, structures,
and components of the dwelling and shall identify material defects
observed. Inspection reports may contain recommendations regarding
conditions reported or recommendations for correction, monitoring or
further evaluation by professionals, but this is not required.
2.1. Roof
I. The inspector shall inspect from
ground level or eaves:
A. The roof covering.
B. The gutters.
C. The downspouts.
D. The vents, flashings, skylights, chimney and other roof
penetrations.
E. The general structure of the roof from the readily
accessible panels, doors or stairs.
II. The inspector is not required to:
A. Walk on any roof surface.
B. Predict the service life expectancy.
C. Inspect underground downspout diverter drainage pipes.
D. Remove snow, ice, debris or other conditions that
prohibit the observation of the roof surfaces.
E. Inspect antennae, lightning arresters, or similar
attachments.
2.2. Exterior
I. The inspector shall inspect:
A. The siding, flashing and trim.
B. All exterior doors, decks, stoops, steps, stairs,
porches, railings, eaves, soffits and fascias.
C. And report as in need of repair
any spacings between intermediate balusters, spindles,
or rails for steps, stairways, balconies, and railings
that permit the passage of an object greater than four
inches in diameter.
D. A representative number of
windows.
E. The vegetation, surface drainage and retaining walls
when these are likely to adversely affect the structure.
F. And describe the exterior wall covering.
II. The inspector is not required to:
A. Inspect or operate screens,
storm windows, shutters, awnings, fences, outbuildings, or
exterior accent lighting.
B. Inspect items, including window and door flashings, which
are not visible or readily accessible from the ground.
C. Inspect geological, geotechnical, hydrological and/or
soil conditions.
D. Inspect recreational facilities.
E. Inspect seawalls, break-walls and docks.
F. Inspect erosion control and earth stabilization measures.
G. Inspect for safety type glass.
H. Inspect underground utilities.
I. Inspect underground items.
J. Inspect wells or springs.
K. Inspect solar systems.
L. Inspect swimming pools or spas.
M. Inspect septic systems or cesspools.
N. Inspect playground equipment.
O. Inspect sprinkler systems.
P. Inspect drain fields or drywells.
Q. Determine the integrity of the thermal window seals or
damaged glass.
2.3. Basement,
Foundation & Crawlspace
I. The inspector shall inspect:
A. The basement.
B. The foundation
C. The crawlspace.
D. The visible structural components.
E. And report any present conditions or
clear indications of active water penetration observed
by the inspector.
F. And report any general
indications of foundation movement that are observed by
the inspector, such as but not limited to sheetrock
cracks, brick cracks, out-of-square door frames or floor
slopes.
II. The inspector is not required to:
A. Enter any crawlspaces that are
not readily accessible or where entry could cause damage
or pose a hazard to the inspector.
B. Move stored items or debris.
C. Operate sump pumps with inaccessible floats.
D. Identify size, spacing, span, location or determine
adequacy of foundation bolting, bracing, joists, joist
spans or support systems.
E. Provide any engineering or architectural service.
F. Report on the adequacy of any structural system or
component.
I. The inspector shall inspect:
A. The heating systems using normal
operating controls and describe the energy source and
heating method.
B. And report as in need of repair heating systems which do
not operate.
C. And report if the heating systems are deemed inaccessible
II. The inspector is not
required to:
A. Inspect or evaluate interiors
of flues or chimneys, fire chambers, heat
exchangers, humidifiers, dehumidifiers, electronic air
filters, solar heating systems or fuel tanks.
B. Inspect underground fuel tanks.
C. Determine the uniformity, temperature, flow, balance,
distribution, size, capacity, BTU, or supply adequacy of
the heating system.
D. Light or ignite pilot flames.
E. Activate heating, heat pump systems, or other heating
systems when ambient temperatures or when other
circumstances are not conducive to safe operation or may
damage the equipment.
F. Override electronic thermostats.
G. Evaluate fuel quality.
H. Verify thermostat calibration,
heat anticipation or automatic setbacks, timers,
programs or clocks.
2.5. Cooling
I. The inspector shall inspect:
A. The central cooling equipment
using normal operating controls.
II. The inspector is not required to:
A. Determine the uniformity,
temperature, flow, balance, distribution, size, capacity,
BTU, or supply adequacy of the cooling system.
B. Inspect window units, through-wall units, or electronic
air filters.
C. Operate equipment or systems if exterior temperature is
below 60 degrees Fahrenheit or when other circumstances are
not conducive to safe operation or may damage the equipment.
D. Inspect or determine thermostat calibration, heat
anticipation or automatic setbacks or clocks.
E. Examine electrical current, coolant fluids or gases, or
coolant leakage.
2.6. Plumbing
I. The inspector shall:
A. Verify the presence of and
identify the location of the main water shutoff valve.
B. Inspect the water heating equipment, including
combustion air, venting, connections, energy sources,
seismic bracing, and verify the presence or absence of
temperature-pressure relief valves and/or Watts 210
valves.
C. Flush toilets.
D. Run water in sinks, tubs, and showers.
E. Inspect the interior water supply including all
fixtures and faucets.
F. Inspect the drain, waste and vent systems, including
all fixtures.
G. Describe any visible fuel storage systems.
H. Inspect the drainage sump pumps and test pumps with
accessible floats.
I. Inspect and describe the water supply, drain, waste
and main fuel shut-off valves, as well as the location
of the water main and main fuel shut-off valves.
J. Inspect and determine if the water supply is public
or private.
K. Inspect and report as in need of repair deficiencies
in the water supply by viewing the functional flow in
two fixtures operated simultaneously.
L. Inspect and report as in need of repair deficiencies
in installation and identification of hot and cold
faucets.
M. Inspect and report as in need of repair mechanical
drain-stops that are missing or do not operate if
installed in sinks, lavatories and tubs.
N. Inspect and report as in need of repair commodes that
have cracks in the ceramic material, are improperly
mounted on the floor, leak, or have tank components
which do not operate.
II. The inspector is not required to:
A. Light or ignite pilot flames.
B. Determine the size, temperature, age, life expectancy
or adequacy of the water heater.
C. Inspect interiors of flues or chimneys, water
softening or filtering systems, well pumps or tanks,
safety or shut-of valves, floor drains, lawn sprinkler
systems or fire sprinkler systems.
D. Determine the exact flow rate, volume, pressure,
temperature, or adequacy of the water supply.
E. Determine the water quality or potability or the
reliability of the water supply or source.
F. Open sealed plumbing access panels.
G. Inspect clothes washing machines or
their connections.
H. Operate any main, branch or fixture valve.
I. Test shower pans, tub and
shower surrounds or enclosures for leakage.
J. Evaluate the compliance with local or state
conservation or energy standards, or the proper design
or sizing of any water, waste or venting components,
fixtures or piping.
K. Determine the effectiveness of anti-siphon, back-flow
prevention or drain-stop devices.
L. Determine whether there are sufficient clean-outs for
effective cleaning of drains.
M. Evaluate gas, liquid propane or oil storage tanks.
N. Inspect any private sewage waste disposal system or
component of.
O. Inspect water treatment systems or water filters.
P. Inspect water storage tanks, pressure pumps or
bladder tanks.
Q. Evaluate wait time to
obtain hot water at fixtures, or perform testing of
any kind to water heater elements.
R. Evaluate or determine the
adequacy of combustion air.
S. Test, operate, open or
close safety controls, manual stop valves and/or
temperature or pressure relief valves.
T. Examine ancillary systems
or components, such as, but not limited to, those
relating to solar water heating, hot water
circulation.
U. Determine the existence or
condition of polybutylene plumbing.
2.7. Electrical
I. The inspector shall inspect:
A. The service drop/lateral.
B. The meter socket enclosures.
C. The means for disconnecting the service main.
D. And determine the rating of the service amperage.
E. Panelboards and overcurrent devices (breakers and
fuses).
F. The service grounding and bonding.
H. A representative number of switches, receptacles,
lighting fixtures, AFCI receptacles.
I. And test all Ground Fault
Circuit Interrupter (GFCI) receptacles and GFCI circuit
breakers observed and deemed to be GFCI's during the
inspection using a GFCI tester.
J. And report the presence of
solid conductor aluminum branch circuit wiring if
readily visible.
K. And report on any tested GFCI-tested receptacles in
which power was not present, polarity is incorrect, is
not secured to the wall, the cover is not in place, the
ground fault circuit interrupter devices are not
properly installed or do not operate properly, evidence
of arcing or excessive heat is present, or where the
receptacle is not grounded or is not secured to the
wall.
L. The service entrance conductors and the condition of
the conductor insulation.
M. And describe the amperage rating of the service.
N. And report the absence of smoke detectors.
O. Service entrance cables and report as in need of
repair deficiencies in the integrity of the insulation,
drip loop, or separation of conductors at weatherheads
and clearances from grade or rooftops.
II. The inspector is not required to:
A. Insert any tool, probe or device
into the main panelboard, sub-panels, distribution
panelboards, or electrical fixtures.
B. Operate electrical systems that are shut down.
C. Remove panelboard cabinet covers or dead front covers if
they are not readily accessible.
D. Operate overcurrent protection devices.
E. Operate non-accessible smoke detectors.
F. Measure or determine the amperage or voltage of the main
service equipment if not visibly labeled. G. Inspect the
fire or alarm system and components.
H. Inspect the ancillary wiring or remote control devices.
I. Activate any electrical systems or branch circuits which
are not energized.
J. Operate or reset overload devices.
K. Inspect low voltage systems, electrical de-icing tapes,
swimming pool wiring or any time-controlled devices.
L. Verify the service ground.
M. Inspect private or emergency electrical supply sources,
including but not limited to generators, windmills,
photovoltaic solar collectors, or battery or electrical
storage facility.
N. Inspect spark or lightning arrestors.
O. Conduct voltage drop calculations.
P. Determine the accuracy of labeling.
2.8. Fireplace
I. The inspector shall inspect:
A. The fireplace, and open and
close the damper door if readily accessible and operable.
B. Hearth extensions and other permanently installed
components.
C. And report as in need of repair deficiencies in the
lintel, hearth and material surrounding the fireplace,
including clearance from combustible materials
II. The inspector is not required to:
A. Inspect the flue or vent
system.
B. Inspect the interior of chimneys or flues, fire doors
or screens, seals or gaskets, or mantels.
C. Determine the need for a chimney sweep.
D. Operate gas fireplace inserts.
E. Light pilot flames.
F. Determine the appropriateness of any installation.
G. Inspect automatic fuel feed devices.
H. Inspect combustion and/or make-up air devices.
I. Inspect heat distribution assists whether gravity
controlled or fan assisted.
J. Ignite or extinguish fires.
K. Determine draft characteristics.
L. Move fireplace inserts, stoves, or firebox contents.
M. Determine adequacy of draft, perform a smoke test or
dismantle or remove any component.
N. Perform a National Fire
Prevention Association (NFPA) style inspection.
2.9. Attic,
Ventilation & Insulation
I. The inspector shall inspect:
A. The insulation in unfinished
spaces.
B. The ventilation of attic spaces.
C. Mechanical ventilation systems.
D. And report on the general absence or lack of insulation.
II. The inspector is not required to:
A. Enter the attic or any
unfinished spaces that are not readily accessible or
where entry could cause damage or pose a safety hazard
to the inspector in his or her opinion.
B. To move, touch, or disturb insulation.
C. To move, touch or disturb vapor retarders.
D. Break or otherwise damage the surface finish or
weather seal on or around access panels and covers.
E. Identify the composition or exact R-value of
insulation material.
F. Activate thermostatically operated fans.
G. Determine the types of materials used in insulation
or wrapping of pipes, ducts, jackets, boilers, and
wiring.
H. Determine the adequacy of
ventilation.
2.10. Doors, Windows &
Interior
I. The inspector shall:
A. Open and close a representative
number of doors and windows.
B. Inspect the walls, ceilings, steps, stairways, and
railings.
C. And report as in need of
repair any spacing between intermediate balusters,
spindles, or rails for steps, stairways, and
railings that permits the passage of an object
greater than four inches in diameter.
D. Inspect garage doors and garage door openers by
operating first by remote (if available) and then by
the installed automatic door control.
E. And report as in need of repair any installed
electronic sensors that are not operable or not
installed at proper heights above the garage door.
F. And report as in need of repair any door locks or
side ropes that have not been removed or disabled
when garage door opener is in use.
G. And report as in need of repair any windows that
are obviously fogged or display other evidence of
broken seals.
II. The inspector is not required to:
A. Inspect paint, wallpaper, window
treatments or finish treatments.
B. Inspect central vacuum systems.
C. Inspect safety glazing.
D. Inspect security systems or components.
E. Evaluate the fastening of countertops, cabinets, sink
tops and fixtures, or firewall compromises.
F. Move furniture, stored items, or any coverings like
carpets or rugs in order to inspect the concealed floor
structure.
G. Move drop ceiling tiles.
H. Inspect or move any household appliances..
I. Inspect or operate equipment housed in the garage except
as otherwise noted.
J. Verify or certify safe operation of any auto reverse or
related safety function of a garage door.
K. Operate or evaluate any security bar release and opening
mechanisms, whether interior or exterior, including their
compliance with local, state, or federal standards.
L. Operate any system, appliance or component that requires
the use of special keys, codes, combinations, or devices.
M. Operate or evaluate self-cleaning oven cycles, tilt
guards/latches or signal lights.
N. Inspect microwave ovens or test leakage from microwave
ovens.
O. Operate or examine any sauna, steam-jenny, kiln, toaster,
ice-maker, coffee-maker, can-opener, bread-warmer, blender,
instant hot water dispenser, or other small, ancillary
devices.
P. Inspect elevators.
Q. Inspect remote controls.
R. Inspect appliances.
S. Inspect items not permanently installed.
T. Examine or operate any above-ground, movable,
freestanding, or otherwise non-permanently installed
pool/spa, recreational equipment or self-contained
equipment.
U. Come into contact with any pool or spa water in order to
determine the system structure or components.
V. Determine the adequacy of spa jet water force or bubble
effect.
W. Determine the structural integrity or leakage of a pool
or spa.
3.1. Limitations:
I. An inspection is not technically
exhaustive.
II. An inspection will not identify concealed or latent
defects.
III. An inspection will not deal with aesthetic concerns or
what could be deemed matters of taste, cosmetic defects,
etc.
IV. An inspection will not determine the suitability of the
property for any use.
V. An inspection does not determine the market value of the
property or its marketability.
VI. An inspection does not determine
the insurability of the property.
VI. An inspection does not determine the advisability or
inadvisability of the purchase of the inspected property.
VIII. An inspection does not determine the life expectancy
of the property or any components or systems therein.
IX. An inspection does not include items not permanently
installed.
X. These Standards of Practice apply only to homes with four
or fewer dwelling units.
3.2. Exclusions:
I. The inspectors are not required to
determine:
A. Property boundary lines or
encroachments.
B. The condition of any component or system that is not
readily accessible.
C. The service life expectancy of any component or system.
D. The size, capacity, BTU, performance, or efficiency of
any component or system.
E. The cause or reason of any condition.
F. The cause for the need of repair or replacement of any
system or component.
G. Future conditions.
H. Compliance with codes or regulations.
I. The presence of evidence of rodents, animals or insects.
J. The presence of mold, mildew or fungus.
K. The presence of air-borne hazards.
L. The presence of birds.
M. The presence of other flora or fauna.
N. The air quality.
O. The existence of asbestos.
P. The existence of environmental hazards.
Q. The existence of electro-magnetic fields.
R. The presence of hazardous materials including, but not
limited to, the presence of lead in paint.
S. Any hazardous waste conditions.
T. Any manufacturer's recalls or conformance with
manufacturer installation or any information included for
consumer protection purposes.
U. Operating costs of systems.
V. Replacement or repair cost estimates.
W. The acoustical properties of any systems.
X. Estimates of the cost to operating any given system.
II. The inspectors are not required to
operate:
A. Any system that is shut down.
B. Any system that does not function properly.
C. Or evaluate low voltage electrical systems such as, but
not limited to:
1. Phone lines.
2. Cable lines.
3. Antennae.
4. Lights.
5. Remote controls.
D. Any system that does not turn on with the use of normal
operating controls.
E. Any shut off valves or manual stop valves.
F. Any electrical disconnect or over current protection
devices.
G. Any alarm systems.
H. Moisture meters, gas detectors or similar equipment.
III. The inspectors are not required
to:
A. Move any personal items or other
obstructions, such as, but not limited to:
1. Throw rugs.
2. Furniture.
3. Floor or wall coverings.
4. Ceiling tiles
5. Window coverings.
6. Equipment.
7. Plants.
8. Ice.
9. Debris.
10. Snow.
11. Water.
12. Dirt.
13. Foliage.
14. Pets
B. Dismantle, open, or uncover any
system or component.
C. Enter or access any area which may, in the opinion of
the inspector, be unsafe.
D. Enter crawlspaces or other areas that are unsafe or
not readily accessible.
E. Inspect underground items such as, but not limited
to, underground storage tanks or other indications of
their presence, whether abandoned or actively used.
F. Do anything which, in the inspector's opinion, is
likely to be unsafe or dangerous to the inspector or
others or damage property, such as, but not limited to,
walking on roof surfaces, climbing ladders, entering
attic spaces or negotiating with pets.
G. Inspect decorative items.
H. Inspect common elements or areas in multi-unit
housing.
I. Inspect intercoms, speaker systems, radio-controlled,
security devices or lawn irrigation systems.
J. Offer guarantees or warranties.
K. Offer or perform any engineering services.
L. Offer or perform any trade or professional service
other than home inspection.
M. Research the history of the property, report on its
potential for alteration, modification, extendibility,
or its suitability for a specific or proposed use for
occupancy.
N. Determine the age of construction or installation of
any system structure or component of a building, or
differentiate between original construction and
subsequent additions, improvements, renovations or
replacements.
O. Determine the insurability of a property.
P. Perform or offer Phase 1
environmental audits.
Q. Inspect on any system or
component which is not included in these standards.
4.1. Accessible: Can be approached or
entered by the inspector safely, without difficulty, fear or danger.
4.2. Activate: To turn on, supply power, or
enable systems, equipment, or devices to become active by normal
operating controls. Examples include turning on the gas or water
supply valves to the fixtures and appliances and activating
electrical breakers or fuses.
4.3. Adversely Affect: To constitute, or
potentially constitute, a negative or destructive impact.
4.4. Alarm System: Warning devices,
installed or free-standing, including but not limited to: carbon
monoxide detectors, flue gas and other spillage detectors, security
equipment, ejector pumps and smoke alarms.
4.5. Appliance: A household device operated
by use of electricity or gas. Not included in this definition are
components covered under central heating, central cooling or
plumbing.
4.6. Architectural Service: Any practice
involving the art and science of building design for construction of
any structure or grouping of structures and the use of space within
and surrounding the structures or the design, design development,
preparation of construction contract documents, and administration
of the construction contract.
4.7. Component: A permanently installed or
attached fixture, element or part of a system.
4.8. Condition: The visible and conspicuous
state of being of an object.
4.9. Crawlspace: The area within the
confines of the foundation and between the ground and the underside
of the lowest floor structural component.
4.10. Decorative: Ornamental; not required
for the operation of essential systems and components of a home.
4.11. Describe: To report in writing a
system or component by its type, or other observed characteristics,
to distinguish it from other components used for the same purpose.
4.12. Determine: To arrive at an opinion or
conclusion pursuant to examination.
4.13. Dismantle: To open, take apart or
remove any component, device or piece that would not typically be
opened, taken apart or removed by an ordinary occupant.
4.14. Engineering Service: Any professional
service or creative work requiring engineering education, training,
and experience and the application of special knowledge of the
mathematical, physical and engineering sciences to such professional
service or creative work as consultation, investigation, evaluation,
planning, design and supervision of construction for the purpose of
assuring compliance with the specifications and design, in
conjunction with structures, buildings, machines, equipment, works
or processes.
4.15. Enter: To go into an area to
observe visible components.
4.16. Evaluate: To assess the systems,
structures or components of a dwelling.
4.17. Examine: To visually look. See
Inspect.
4.18. Foundation: The base upon which the
structure or wall rests; usually masonry, concrete, or stone, and
generally partially underground.
4.19. Function: The action for which an
item, component, or system is specially fitted or used or for which
an item, component or system exists; to be in action or perform a
task.
4.20. Functional: Performing, or able to
perform, a function.
4.21. Home Inspection: The process by which
an inspector visually examines the readily accessible systems and
components of a home and operates those systems and components
utilizing these Standards of Practice as a guideline.
4.22. Household Appliances: Kitchen and
laundry appliances, room air conditioners, and similar appliances.
4.23. Inspect: To visually look at readily
accessible systems and components safely, using normal operating
controls and accessing readily accessible panels and areas in
accordance with these Standards of Practice.
4.24. Inspected Property: The readily accessible areas of the
buildings, site, items, components, and systems included in the
inspection.
4.25. Inspector: One who performs a real
estate inspection.
4.26. Installed: Attached or connected such
that the installed item requires tool for removal.
4.27. Material Defect: A condition of a
residential real property or any portion of it that would have a
significant adverse impact on the value of the real property or that
involves an unreasonable risk to people on the property. The fact
that a structural element, system or subsystem is near, at or beyond
the end of the normal useful life of such a structural element,
system or subsystem is not by itself a material defect.
4.28. Normal Operating Controls: Devices
such as thermostats that would be operated by ordinary occupants
which require no specialized skill or knowledge.
4.29. Observe: To see through visually
directed attention.
4.30. Operate: To cause systems to function
or turn on with normal operating controls.
4.31. Readily Accessible: An item or
component is readily accessible if, in the judgment of the
inspector, it is capable of being safely observed without the
removal of obstacles, detachment or disengagement of connecting or
securing devices, or other unsafe or difficult procedures to gain
access.
4.32. Recreational Facilities: Spas,
saunas, steam baths, swimming pools, tennis courts, playground
equipment, and other exercise, entertainment or athletic facilities.
4.33. Report: A written communication
(possibly including images) of any material defects seen during the
inspection.
4.34. Representative Number: A sufficient
number to serve as a typical or characteristic example of the item(s)
inspected.
4.35. Safety Glazing: Tempered glass,
laminated glass, or rigid plastic.
4.36. Shut Down: Turned off, unplugged,
inactive, not in service, not operational, etc.
4.37. Structural Component: A component
which supports non-variable forces or weights (dead loads) and
variable forces or weights (live loads).
4.38. System: An assembly of various
components which function as a whole.
4.39. Technically Exhaustive: A
comprehensive and detailed examination beyond the scope of a real
estate home inspection which would involve or include, but would not
be limited to: dismantling, specialized knowledge or training,
special equipment, measurements, calculations, testing, research,
analysis or other means.
4.40. Unsafe: A condition in a system or
component which is judged to be a significant risk of personal
injury during normal, day-to-day use. The risk may be due to damage,
deterioration, improper installation or a change in accepted
residential construction standards.
4.41. Verify: To confirm or substantiate.
|